Specification revision: Numerical examples below refer to the July 2026 configurations already documented on this website. A model suffix may have different construction revisions. Confirm the current datasheet, drawing, BOM and installation document for the offered configuration; do not apply historical values to a different version.
Direct answer: The published minimum bending radius on this page is 0.5 m for the XSFM-560-T2 560W frameless flexible configuration. It is a model-specific installation boundary, not approval for every curved roof. Check the roof's continuous profile, local transitions, current model documents and site measurements before freezing a layout.
What the minimum radius tells you
The radius describes a smooth curve that may be evaluated for the named configuration under suitable project conditions. A larger radius is gentler. Use the current installation document for the exact model and structure version; do not transfer the value to another configuration.
What it does not establish
- It does not mean the module may be folded, creased or repeatedly bent.
- It does not establish compatibility with every curved roof.
- It does not prove the roof structure, substrate, fixing method, waterproofing or local wind and snow design is suitable.
- It does not replace review of the full roof profile and actual site conditions.
Check the continuous curve and local changes
A roof can look uniformly curved in a plan while having a local flat spot, abrupt step, seam-height change, repair patch or unsupported transition. Review the surface across the whole proposed module area, including where the curve starts and ends. Record local features rather than treating one overall radius as a complete description.
Roof drawing and site-survey checklist
- Confirm the latest roof plan, sections, profile information, drawing revision and survey date.
- Mark the intended module rows, roof seams, drains, penetrations, obstacles and changes in roof direction.
- Compare the drawings with site measurements and located photographs, especially at curve transitions, joints, steps and repair areas.
- Log each difference with its location, drawing revision, evidence, responsible reviewer and resolution; do not silently redraw a mismatch.
- Ask the project engineer and the relevant roof-system and PV suppliers to review open geometry, substrate and attachment questions before layout approval.
Information to request before a preliminary review
- The exact module model and current installation document for that configuration.
- Roof plans and sections, the roof build-up and available profile or survey records.
- Site photographs labelled with location and direction, plus a list of drawing-to-site differences.
- Roof material and condition, drainage and waterproofing interfaces, permitted attachment constraints and any relevant roof-system requirements.
- The proposed array layout and fixing concept, with project-specific structural review assigned to the responsible engineer.
Frequently asked questions
Does the published 0.5 m radius mean the module fits every roof with that curve?
No. It is the published limit for the named XSFM-560-T2 configuration. The roof's continuous shape, local transitions, substrate, attachment and project design still need review.
How should a local flat spot or step be handled?
Record its position and dimensions from the survey, compare it with the current drawings and request the responsible engineer and suppliers to confirm the disposition. Do not assume a universal tolerance.
What if site measurements differ from the drawings?
Keep the discrepancy visible in the revision log, obtain or confirm the current survey information and resolve the difference with the responsible reviewers before the layout is frozen.
Project reference and limits
Curved metal roof project reference. X-SOLAR reports that the 2.5 MW Tangshan Jinzhou Steel Plant project in Hebei used X-SOLAR 560 W flexible modules and adhesive fixing on a continuous curved industrial metal roof and is grid-connected. The supplied module model has not been publicly disclosed. For an initial review, use the project enquiry checklist to submit measured sections, seam and transition locations, substrate and coating details, drainage, site photos and design wind inputs.
Related resources: curved-roof assessment checklist · Tangshan project case · XSFM-560-T2 product page.
For a preliminary review, share the exact model under consideration, current roof drawings and survey date, roof build-up, labelled site photographs, known local profile changes, intended layout and the proposed attachment approach. Identify unresolved assumptions and who will review them.