X-Solar BIPV Tile Series Comparison: 50W Curved, 120W Flat, 520W Steel-Tile

When comparing building-integrated roof products, keep power, dimensions and weight tied to the same model and unit basis. Do not present a per-tile mass as a roof-area load, and do not treat external dimensions as a project’s effective coverage area. The values below are from X-Solar’s official product and news pages (July 2026 documentation).

What each model is

Model Form Power Efficiency Dimensions (mm) Mass Construction notes
XSDCM-50-H Curved tile (traditional tile profile) 50 W 23.8% 685 × 420 × 9 5.5 kg per tile 9 HJT cells (3×3); IP68; 5400/2400 Pa; 15-yr product / 30-yr linear power warranty
XSDFM-120-T Flat tile 120 W 23.5% 1630 × 440 × 29 9.5 kg per tile 32 N-TOPCon cells (2×16); IP68; 5400/2400 Pa; 15-yr product / 30-yr linear power warranty
XSCM-520-T Steel-tile BIPV module 520 W 23.5% 2400 × 1314 × 4 28 kg (~9.0 kg/m²) 132 N-TOPCon cells (11×12); IP68; 5400/2400 Pa; 12-yr product / 25-yr linear power warranty

Which roofs are they intended to discuss?

XSDCM-50-H (curved)

  • Provides a traditional tile exterior as a concrete reference for architectural discussion.
  • Curved form is a product characteristic, not confirmation of suitability for every pitched roof.
  • Building design must still verify tile module fit, overlaps, waterproofing, structure and drainage.

XSDFM-120-T (flat)

  • Useful as a flat-tile baseline that keeps power, size and per-tile weight on one model line.
  • Retain the “per tile” unit; do not convert 9.5 kg/tile into an unverified roof-area load.
  • External size is not the project coverage area after overlaps and edge detailing.

XSCM-520-T (steel-tile)

  • Aimed at roof-envelope integration discussions with higher power per module.
  • Record 28 kg and ~9.0 kg/m² with the full model name and official source.
  • Envelope-integration intent is not proof of installation details or waterproofing for a given project.

Beyond the comparison table

Confirm roof type and slope, structural / wind / snow inputs, attachment and drainage interfaces, electrical design, and the datasheet / drawing / warranty set for the exact offered revision. A few published parameters can start the conversation; they cannot determine the installation outcome for an entire roof.

Electrical and warranty notes (published values only)

  • XSDCM-50-H: Vmp 5.98 V / Imp 8.37 A; Voc 6.69 V / Isc 8.62 A; 15-year product / 30-year linear power warranty.
  • XSDFM-120-T: Vmp 9.59 V / Imp 12.50 A; Voc 10.99 V / Isc 13.26 A; 15-year product / 30-year linear power warranty.
  • XSCM-520-T: Vmp 39.25 V / Imp 13.25 A; Voc 48.52 V / Isc 13.92 A; 12-year product / 25-year linear power warranty.

Stringing and inverter matching must follow these electrical values. Tile products have relatively low per-tile voltage, so string length and cable loss need explicit design attention.

A practical comparison record

For each candidate model, keep one row with: full model name, power, dimensions, per-tile or module mass with units, efficiency, source URL, and open roof-interface questions. News pages explain unit discipline; they do not replace the product-page parameter table.

How this series relates to flexible / framed lightweight modules

BIPV tiles and steel-tile modules address roof-envelope integration. They are a different product family from XSFM frameless flexible modules and from XSLM framed single-glass modules. A project may evaluate more than one family, but each comparison table should stay inside one family first, then document why a second family is or is not being considered. Mixing per-tile masses with per-module area masses without labelling the unit will create false rankings.

This article restates published product facts only and is not a project approval.