Flexible vs Framed Lightweight Modules: How to Choose for a Roof Project (X-Solar)
Selecting modules for a lightweight rooftop PV project is not a power-rating exercise alone. Match roof geometry, remaining structural capacity, attachment method, handling / O&M access, and the exact published model revision. The figures below are taken from X-Solar product pages (July 2026 documentation). Site suitability still requires project-specific engineering review.
Definitions
- Frameless flexible module: No frame; may bend during installation to follow a suitable curved roof within a published minimum radius. A radius limit is an installation boundary, not approval for folding or cyclic bending.
- Framed lightweight module: Keeps a frame for rails / clamps on suitable flat or low-slope roofs; heavier than the matching flexible version but still lighter than many conventional glass modules.
- Framed single-glass lightweight module (XSLM-440W): 1.1 mm single-glass, framed construction. It is not a bendable flexible module and must not be selected using a flexible-module radius.
Published reference models
| Model | Construction | Power | Efficiency | Dimensions (mm) | Mass | Area mass |
|---|---|---|---|---|---|---|
| XSFM-380-T1 | Frameless flexible | 380 W | 23.5% | 1520 × 1200 × 2.7 | 5.7 kg | ~3.1 kg/m² |
| XSFM-430-T1 | Frameless flexible | 430 W | 23.5% | 1750 × 1150 × 2.7 | 6.2 kg | ~3.1 kg/m² |
| XSFM-430-T2 | Frameless flexible | 430 W | 23.5% | 2260 × 918 × 2.7 | 6.4 kg | ~3.1 kg/m² |
| XSFM-560-T2 frameless | Frameless flexible | 560 W | 23.5% | 2260 × 1200 × 2.7 | 8.4 kg | ~3.1 kg/m² |
| XSFM-560-T2 framed | Framed lightweight | 560 W | 23.5% | 2260 × 1245 × 25 | 13.5 kg | ~4.8 kg/m² |
| XSLM-440W (1.1 mm glass) | Framed single-glass | 440 W | 23.5% | 1721 × 1133 × 30 | 9.5 kg | ~4.8 kg/m² |
For the referenced XSFM-560-T2 frameless configuration, the published minimum bending radius is 0.5 m. The framed configuration is not assigned that flexible radius. Module mass is not the complete PV-system load.
Decision cues
Lean toward frameless flexible (380 / 430 / 560 frameless) when:
- The roof has suitable continuous curvature that can be checked against the installation radius;
- Lower module area mass is valuable given verified structural limits;
- An adhesive system or aluminium square-tube substructure can be validated for the substrate and coating.
Lean toward framed lightweight (560 framed or XSLM-440W) when:
- The roof is mainly flat or low-slope and conventional rails / clamps fit the design;
- Teams prefer framed handling and clamping logistics;
- The requirement is framed single-glass lightweight performance without flexible bending (use XSLM-440W and state that clearly).
Boundaries that must stay visible
- Frameless modules are not designed for repeated or cyclic bending after installation.
- Published static load ratings differ: flexible series commonly list 5400 Pa front / 2400 Pa rear; XSLM-440W lists 2400 Pa front / 1000 Pa rear — do not mix tables.
- Certificates, warranty terms and BOM must match the exact model suffix offered.
What to send with an enquiry
Location, roof type with drawings / photos, usable area, structural capacity notes, proposed attachment constraints, electrical scope and schedule. Contact X-Solar via the official site or sales@x-solarenergy.com for configuration matching against the current revision.
Same power, different footprints — the 430 W example
Both XSFM-430-T1 (1750 × 1150 × 2.7 mm, 6.2 kg) and XSFM-430-T2 (2260 × 918 × 2.7 mm, 6.4 kg) are rated 430 W. Choose by roof panel size, orientation and keep-outs, not by wattage alone. A shorter/wider versus longer/narrower footprint can change cable routes, access paths and how the module sits on a curved surface; lay out both options on drawings before locking a SKU.
Why the 560 W platform offers frameless and framed builds
XSFM-560-T2 publishes two constructions at the same 23.5% efficiency: frameless for suitable curved / low-load discussions, and framed for rail-and-clamp formats on flat or low-slope roofs. Dimensions, mass and installation boundaries differ. Quotations and certificates must state which construction is offered.
Frequent mistakes to avoid
- Treating the minimum bending radius as permission to roll, fold or cyclically bend the module;
- Classifying XSLM-440W as a flexible module;
- Using module area mass as a substitute for full-system structural checks;
- Mixing static-load or electrical tables across model suffixes.
This article restates published product facts only. It is not an installation approval for any specific roof.